https://issues.apache.org/jira/browse/NIFI-5645?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16645427#comment-16645427
 ] 

ASF GitHub Bot commented on NIFI-5645:
--------------------------------------

Github user mcgilman commented on a diff in the pull request:

    https://github.com/apache/nifi/pull/3037#discussion_r224205359
  
    --- Diff: 
nifi-nar-bundles/nifi-windows-event-log-bundle/nifi-windows-event-log-processors/src/main/java/org/apache/nifi/processors/windows/event/log/ConsumeWindowsEventLog.java
 ---
    @@ -199,6 +230,8 @@ private String subscribe(ProcessContext context) throws 
URISyntaxException {
     
             subscriptionHandle = wEvtApi.EvtSubscribe(null, null, channel, 
query, null, null,
                     evtSubscribeCallback, 
WEvtApi.EvtSubscribeFlags.SUBSCRIBE_TO_FUTURE | 
WEvtApi.EvtSubscribeFlags.EVT_SUBSCRIBE_STRICT);
    +        lastActivityTimestamp = System.currentTimeMillis();
    --- End diff --
    
    Just wanted to clarify the logic here... Do we want to update the 
`lastActivityTimestamp` when the client was unable to subscribe? Could that 
lead to premature reconnection later?


> Auto reconnect ConsumeWindowsEventLog if no log is consumed for configured 
> time period
> --------------------------------------------------------------------------------------
>
>                 Key: NIFI-5645
>                 URL: https://issues.apache.org/jira/browse/NIFI-5645
>             Project: Apache NiFi
>          Issue Type: Improvement
>          Components: Extensions
>    Affects Versions: 1.0.0
>            Reporter: Koji Kawamura
>            Assignee: Koji Kawamura
>            Priority: Major
>
> While ConsumeWindowsEventLog is running, if Windows Event Log service is 
> restarted, or ERROR_EVT_QUERY_RESULT_STALE (15011) is returned, the processor 
> keeps running, but will not receive further log events.
> Current work-around is restarting the processor manually.
> We could implement auto-reconnect logic like below, so that the processor can 
> recover from such situation automatically.
> * Add a new processor property, ''Inactive duration to reconnect", e.g. "3 
> mins"
> * At onTrigger, check how long has it passed since the last message was 
> received. If it exceeds the configured duration, reset the consumer



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)