siddhantsangwan commented on code in PR #8460: URL: https://github.com/apache/ozone/pull/8460#discussion_r2160931983
########## hadoop-hdds/docs/content/design/full-volume-handling.md: ########## @@ -0,0 +1,166 @@ +--- +title: Full Volume Handling +summary: Immediately trigger Datanode heartbeat on detecting full volume +date: 2025-05-12 +jira: HDDS-12929 +status: Design +author: Siddhant Sangwan, Sumit Agrawal +--- + +<!-- + Licensed under the Apache License, Version 2.0 (the "License"); + you may not use this file except in compliance with the License. + You may obtain a copy of the License at + + http://www.apache.org/licenses/LICENSE-2.0 + + Unless required by applicable law or agreed to in writing, software + distributed under the License is distributed on an "AS IS" BASIS, + WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. + See the License for the specific language governing permissions and + limitations under the License. See accompanying LICENSE file. +--> + +## Summary +On detecting a full Datanode volume during write, immediately trigger a heartbeat containing the latest storage +report for all volumes. + +## Problem +When a Datanode volume is close to full, the SCM may not be immediately aware of this because storage reports are only +sent to it every one minute (`HDDS_NODE_REPORT_INTERVAL_DEFAULT = "60s"`). We would like SCM to know about this as +soon as possible, so it can make an informed decision when checking the volumes in that Datanode for deciding whether a +new pipeline can contain that Datanode (in `SCMCommonPlacementPolicy.hasEnoughSpace`). + +Additionally, SCM only has stale +information about the current size of a container because container size is only updated when an Incremental Container +Report (event based, for example when a container transitions from open to closing state) is received or a Full +Container Report (`HDDS_CONTAINER_REPORT_INTERVAL_DEFAULT = "60m"`) is received. This can lead to the SCM +over-allocating blocks to containers on a full DN volume. When the writes eventually fail, performance will drop +because the client will have to request for a different set of blocks. We will discuss how we tried to solve this, +but ultimately decided to not go ahead with the solution. Review Comment: The design changed a lot. We've already merged the corresponding implementation - https://github.com/apache/ozone/pull/8590, and I've updated this doc now. This comment will tell you why and what changed - https://github.com/apache/ozone/pull/8492#issuecomment-2954967269 This comment and the design doc itself will tell you what we implemented - https://github.com/apache/ozone/pull/8590#issue-3129500113 In short, we trigger heartbeat immediately including the close container action. Per container throttling. Not sending storage reports. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected] --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]
