Tsz-wo Sze created HDDS-17684:
---------------------------------
Summary: For under-construction blocks, bound reads to the hsync'd
length.
Key: HDDS-17684
URL: https://issues.apache.org/jira/browse/HDDS-17684
Project: Apache Ozone
Issue Type: Sub-task
Components: Ozone Client
Reporter: Tsz-wo Sze
Claude:
Reads. BlockInputStream reads up to the OM block length, except for an
under-construction (hsync'd) block, where it uses the length from whichever
datanode answers (blockData.getSize()). A reader may then see bytes that were
not all-acked. We must bound such reads to the hsync'd length.
--