On 1/8/10, Sebastien Lelong <[email protected]> wrote: > Hi Vasile/Wesley, > > > 2010/1/8 vasile surducan <[email protected]> > >> >> For some newest PIC18, the actual jal AD library isn't the best option >> from the speed perspective, because on PIC18 you don't need to wait for the >> aquisition time in the same fashion like on PIC16. >> > > Call you tell me more about acquisiation time ? And which PIC18 are > considered newest ? >
Please take a look to chapter "Selecting and Configuring Automatic Aquisition Time" of the PIC18F25J10. Probably this is actual for other PIC18. Vasile (Wesley)--