DO NOT REPLY TO THIS EMAIL, BUT PLEASE POST YOUR BUG RELATED COMMENTS THROUGH THE WEB INTERFACE AVAILABLE AT <http://nagoya.apache.org/bugzilla/show_bug.cgi?id=22820>. ANY REPLY MADE TO THIS MESSAGE WILL NOT BE COLLECTED AND INSERTED IN THE BUG DATABASE.
http://nagoya.apache.org/bugzilla/show_bug.cgi?id=22820 max value on counter cannot be cleared Summary: max value on counter cannot be cleared Product: JMeter Version: 1.9.1 Platform: PC OS/Version: Windows XP Status: NEW Severity: Minor Priority: Other Component: HTTP AssignedTo: [EMAIL PROTECTED] ReportedBy: [EMAIL PROTECTED] The Counter pre-processor's maximum value cannot be cleared once set. This tends to occur when initially limiting a counter's value to 1 during testing, then being unable to clear it later. The other fields on the Counter form work as expected. The workaround is to type a high value (9999) in the max field. To reproduce: 1. Add Thread Group 2. Add Pre-Processer > Counter to Thread Group. 3. Set Maximum Value to 9 4. Click Thread Group to change focus. 5. Click back to Counter, delete Maximum Value of 9. 6. Click Thread Group to change focus 7. Click back to Counter and note Maximum remains set to 9, instead of blank as expected. --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]