I think that's been there forever. HC have 0 partial charge, so it is
never saved, then its absence is flagged.

On Mon, Aug 24, 2015 at 10:10 AM, Otis Rothenberger <osrot...@chemagic.com>
wrote:

> Bob,
>
> I don’t have your original note, so I have to put this in a new chain.
>
> I’m working on tidying up model kit code, so I’ll try to do some testing
> as I do this. One thing jumped out immediately:
>
> select *;calculate partialcharge;isosurface resolution 0 vdw color range
> -.07 .07 map mep translucent;echo
>
> produces this error:
>
>
> script ERROR: No partial charges were read from the file; Jmol needs these
> to render the MEP data.
> ----
>         isosurface resolution 0 vanderWaals color range -0.07 0.07
> mapProperty >> mep << translucent
>
>
> It appears to be limited to hydrocarbons, so I guess its the MMFF94
> assignment of zero to all atoms. A work around is possible, but I know you
> don’t like work arounds.
>
>
------------------------------------------------------------------------------
_______________________________________________
Jmol-users mailing list
Jmol-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/jmol-users

Reply via email to