Also, the service PICs (monitoring/adaptive/ms-) would only be a MUST
if you want to export the records to a cflowd server with version9 format.

Cheers,
Erdem


On Sat, Jul 19, 2008 at 10:17 AM, Stefan Fouant <[EMAIL PROTECTED]> wrote:
> Nope you can do flow export without the Monitoring/AS/MS-PICs but
> you'll probably want to drop that sampling rate down pretty low... say
> 1:500 or 1:1000 in order to reduce the performance impact; without
> these pics the sampling and flow export is done on the RE.
>
>
>
> On 7/19/08, Samit <[EMAIL PROTECTED]> wrote:
>> Hi list,
>>
>> Like in Cisco router, in order to export flows from Juniper router to
>> external flow collector/analyzer and visualizer, does the adaptive
>> service pic or monitoring service pic is required compulsory?
>>
>> Regards,
>> Samit
>>
>> _______________________________________________
>> juniper-nsp mailing list juniper-nsp@puck.nether.net
>> https://puck.nether.net/mailman/listinfo/juniper-nsp
>>
>
> --
> Sent from Gmail for mobile | mobile.google.com
>
> Stefan Fouant
> Principal Network Engineer
> NeuStar, Inc. - http://www.neustar.biz
> GPG Key ID: 0xB5E3803D
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp