Thanks Hangu.
David
________________________________
De : Hangu Jeong [mailto:[EMAIL PROTECTED]
Envoyé : mardi 14 octobre 2008 03:40
À : ROY David DTF/DERX
Cc : [email protected]
Objet : Re: [j-nsp] Limitation Aggreate Ethernet T-series
Hi David,
As I know, there is no any interface limitation of AE but some SFP, IQ
specific features not supported on AE.
For more detail information, check below link
http://www.juniper.net/techpubs/software/junos/junos84/swconfig84-network-interfaces/id-12190637.html#id-12190637
Regards,
Hangu
On Mon, Oct 13, 2008 at 7:51 PM, <[EMAIL PROTECTED]> wrote:
Hi all,
The maximum number of AE that we can set on the chassis is 128,
but is
there any limitations for some kind of FPC or PIC ? If not, Why
this
number is configurable ?
Thanks,
Regards,
David
*********************************
This message and any attachments (the "message") are
confidential and intended solely for the addressees.
Any unauthorised use or dissemination is prohibited.
Messages are susceptible to alteration.
France Telecom Group shall not be liable for the message if
altered, changed or falsified.
If you are not the intended addressee of this message, please
cancel it immediately and inform the sender.
********************************
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
*********************************
This message and any attachments (the "message") are confidential and intended
solely for the addressees.
Any unauthorised use or dissemination is prohibited.
Messages are susceptible to alteration.
France Telecom Group shall not be liable for the message if altered, changed or
falsified.
If you are not the intended addressee of this message, please cancel it
immediately and inform the sender.
********************************
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp