Hi,
Has any body experience of setting up RPM probes between MPLS/VPN PEs
whilst using AS PIC for time stamping and CoS?
 
I've tried to put the SP interface into the VPN without success, hence
the return route is unknown to the far end. Using M-series on 8.1 code,
it doesn't look like I can change probe source address  when using the
SP :-( Any other ideas?
 
Thanks,
 
Tim.