hello, i have problem with SRX 3600 clusters . in fact i had configure SRX cluster in active passive configuration ,but the node 0 is down like shown with show chassis cluster status command.
ad...@fw2> show chassis cluster status Cluster ID: 1 Node Priority Status Preempt Manual failover Redundancy group: 0 , Failover count: 3 node0 200 disabled no no node1 100 primary no no Redundancy group: 1 , Failover count: 17 node0 0 disabled yes no node1 100 primary yes no in fact we did suspect that it is an issue witch HA control link, we did relace it but the problem persists. and when i diplay the chassis alarms is what a have in node 0: node0: -------------------------------------------------------------------------- 1 alarms currently active Alarm time Class Description 2010-06-04 09:26:02 UTC Minor Check FPC 0 Fabric Chip Chassis Cluster Configuration ===================== set chassis cluster cluster-id 1 node 0 reboot set chassis cluster cluster-id 1 node 1 reboot Data Fabric Configuration ===================== set interfaces fab0 fabric-options member-interfaces ge-0/0/7 set interfaces fab1 fabric-options member-interfaces ge-13/0/7 thanks , _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp