On Wed, Apr 13, 2011 at 12:11 PM, <david....@orange-ftgroup.com> wrote: > Does anybody know if Juniper's MPC cards support SFP+ ZR (80km) modules ?
They work. It's just junos doesn't recognise them (yet) ------ show interfaces diagnostics optics xe-5/3/1 Physical interface: xe-5/3/1 Laser bias current : 62.206 mA Laser output power : 1.7770 mW / 2.50 dBm Receiver signal average optical power : 0.0352 mW / -19.53 dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Module voltage high alarm : Off Module voltage low alarm : Off Module voltage high warning : Off Module voltage low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Laser bias current high alarm threshold : 85.000 mA Laser bias current low alarm threshold : 10.000 mA Laser bias current high warning threshold : 80.000 mA Laser bias current low warning threshold : 12.000 mA Laser output power high alarm threshold : 5.0110 mW / 7.00 dBm Laser output power low alarm threshold : 0.5010 mW / -3.00 dBm Laser output power high warning threshold : 3.9810 mW / 6.00 dBm Laser output power low warning threshold : 0.6310 mW / -2.00 dBm Module temperature high alarm threshold : 85 degrees C / 185 degrees F Module temperature low alarm threshold : -10 degrees C / 14 degrees F Module temperature high warning threshold : 80 degrees C / 176 degrees F Module temperature low warning threshold : -5 degrees C / 23 degrees F Module voltage high alarm threshold : 3.700 V Module voltage low alarm threshold : 2.900 V Module voltage high warning threshold : 3.599 V Module voltage low warning threshold : 3.000 V Laser rx power high alarm threshold : 0.2512 mW / -6.00 dBm Laser rx power low alarm threshold : 0.0020 mW / -26.99 dBm Laser rx power high warning threshold : 0.1995 mW / -7.00 dBm Laser rx power low warning threshold : 0.0025 mW / -26.02 dBm ---- --- show chassis hardware Hardware inventory: Item Version Part number Serial number Description PIC 3 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 1 REV 01 740-011613 H36TR015 UNKNOWN --- _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp