Here is piece of perl script from my Cacti server that polls RPM data:
my $jnxRpmResCalcAverage = '.1.3.6.1.4.1.2636.3.50.1.3.1.5';
my $jnxRpmResCalcPkToPk = '.1.3.6.1.4.1.2636.3.50.1.3.1.6';

This should give you an idea. Probe name is most probably encoded in OID.

Nick

On Wed, Mar 21, 2012 at 1:21 PM, Shiva S Narayana <sshankar...@yahoo.com>wrote:

> Hi, Has anyone implemented RPM in juniper M/MX or J series routers ? I'm
> trying to find a way to pollthe RPM probe results via SNMP. The problem is
> that, the MIBs are proprietyto Juniper and the snmp mibwalk results doesn't
> correlate probe-name if you have multiple probes.
>
> tested in junos 9.3R4. Any help is appreciated.
>
> Thanks
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>