Hi Paris, The VC is 2 members QFX5100-VC:
> show version | grep "fpc|model|os software" fpc0: -------------------------------------------------------------------------- Model: qfx5100-48s-6q JUNOS Base OS Software Suite [13.2X51-D25.2] fpc1: -------------------------------------------------------------------------- Model: qfx5100-48s-6q JUNOS Base OS Software Suite [13.2X51-D25.2] Following configuration is applied: > show configuration groups | display set set groups node0 when member member0 set groups node0 system host-name member0 set groups node0 interfaces em0 unit 0 family inet address 10.10.10.1/24 set groups node1 when member member1 set groups node1 system host-name member1 set groups node1 interfaces em0 unit 0 family inet address 10.10.10.2/24 > show configuration apply-groups | display set set apply-groups node0 set apply-groups node1 So I can ping and access both routing engines remotely: > ssh 10.10.10.1 Password: --- JUNOS 13.2X51-D25.2 built 2014-07-26 05:43:18 UTC {master:0} > > ssh 10.10.10.2 Password: --- JUNOS 13.2X51-D25.2 built 2014-07-26 05:43:18 UTC warning: This chassis is operating in a non-master role as part of a virtual-chassis (VC) system. warning: Use of interactive commands should be limited to debugging and VC Port operations. warning: Full CLI access is provided by the Virtual Chassis Master (VC-M) chassis. warning: The VC-M can be identified through the show virtual-chassis status command executed at this console. warning: Please logout and log into the VC-M to use CLI. {backup:1} > Thanks, Plamen On Wed, Mar 25, 2015 at 10:06 AM, Paris Arau <pa...@juniper.net> wrote: > Hi Plamen, > > > I tried similar configuration(both with and without condition) and I¹m not > able to get this working. > > set groups node0 when member member0 > set groups node0 system host-name member0 > set groups node0 interfaces em0 unit 0 family inet address > 172.30.159.250/23 > set groups node1 when member member1 > set groups node1 system host-name member1 > set groups node1 interfaces em0 unit 0 family inet address > 172.30.159.251/23 > > > If FPC1 is the master, it¹s working just fine but when I¹m pinging FPC0, I > get this: > > lab@UBUNTU:~$ ping 172.30.159.251 > PING 172.30.159.251 (172.30.159.251) 56(84) bytes of data. > 64 bytes from 172.30.159.251: icmp_seq=1 ttl=64 time=0.319 ms > ^C > --- 172.30.159.251 ping statistics --- > 1 packets transmitted, 1 received, 0% packet loss, time 0ms > rtt min/avg/max/mdev = 0.319/0.319/0.319/0.000 ms > lab@UBUNTU:~$ ping 172.30.159.250 > PING 172.30.159.250 (172.30.159.250) 56(84) bytes of data. > From 172.30.159.251: icmp_seq=1 Redirect Host(New nexthop: 172.30.159.250) > From 172.30.159.251: icmp_seq=2 Redirect Host(New nexthop: 172.30.159.250) > ^C > --- 172.30.159.250 ping statistics --- > 2 packets transmitted, 0 received, 100% packet loss, time 1008ms > > lab@UBUNTU:~$ > > > If I¹ll do the master switchover, then it will be the other way around. > > Is there anything else that needs to be configured? What release are you > using? > > > > Thanks, > Paris > > On 25/03/15 10:40, "Plamen Stoev" <plamen.st...@profitbricks.com> wrote: > > >Hi All, > > > >It is possible to configure each VC member to have its own em0 > >configuration and it works very fine. > > > >You need to apply something like following: > > > >node0 { > > when { > > member member0; > > } > > system { > > host-name member0; > > } > > interfaces { > > em0 { > > description "member0 em0 interface"; > > unit 0 { > > family inet { > > address 10.10.10.1/24; > > } > > } > > } > > } > >} > >node1 { > > when { > > member member1; > > } > > system { > > host-name member1; > > } > > interfaces { > > em0 { > > description "member1 em0 interface"; > > unit 0 { > > family inet { > > address 10.10.10.2/24; > > } > > } > > } > > } > >} > >apply-groups [ node0 node1 ]; > > > >Thanks, > >Plamen > > > > > >On Wed, Mar 25, 2015 at 9:20 AM, Tore Anderson <t...@fud.no> wrote: > > > >> * james list <jameslis...@gmail.com> > >> > >> > on QFX VC is there a way to configure VME interface to respond on each > >> > module of the VC instead to be redirected on the master RE ? > >> > > >> > If yes a little configuration example is appreciated. > >> > >> I haven't tried QFX, but on EX you can use apply-groups to match > >> individual members in the VC, and set up different addressing on each > >> member's "me0" interface (note: you will *not* be using "vme"). > >> > >> See http://kb.juniper.net/InfoCenter/index?page=content&id=KB15556 > >> > >> Try it and let the list know if it works on QFX too? > >> > >> Tore > >> _______________________________________________ > >> juniper-nsp mailing list juniper-nsp@puck.nether.net > >> https://puck.nether.net/mailman/listinfo/juniper-nsp > >> > >_______________________________________________ > >juniper-nsp mailing list juniper-nsp@puck.nether.net > >https://puck.nether.net/mailman/listinfo/juniper-nsp > _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp