Hi,
We had issues with port 1 of 3 switches, it was more power related
than a physical issue in our case.
Once we replaced then with SRs the issue went away but only 1 set
lasted, and it was the 0,2 aeX.
-----
Alain Hebert aheb...@pubnix.net
PubNIX Inc.
50 boul. St-Charles
P.O. Box 26770 Beaconsfield, Quebec H9W 6G7
Tel: 514-990-5911 http://www.pubnix.net Fax: 514-990-9443
On 12/05/17 10:59, Benoit Plessis wrote:
Le 05/12/2017 à 16:40, Alain Hebert a écrit :
Rofl,
That's why!!!
We where wondering why 0 & 2 worked but not 0 & 1.
Did you mean you were able to plug them in and they didn't work ?
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp