On 4 June 2018 at 13:46, Martin T <m4rtn...@gmail.com> wrote: > Hi!
Hi! > When I deploy a vMX using orchestration scripts, then I end up with > following virtualized topology: > > https://i.imgur.com/bBTXGM0.png > > Now when I execute "file copy root@192.168.122.1:/tmp/1G_file > /dev/zero" in vMX, then I can see that traffic traverses > virbr0[ge-0.0.0-vmx1] <-> [ge-0/0/0]vcp-vmx1[em1] <-> > [vcp-int-vmx1]br-int-vmx1[vfp-int-vmx1] <-> [int]vfp-vmx1. Am I > misunderstaning this? Or does it really work in a way that first the > VM running Junos receives the traffic, then forwards it to VM running > virtualized Trio and then the traffic is forwarded back to Junos VM? Have I missed something in relation to your topology/config; ge-0/0/0, is that meant to provide you with management access to the VCP or is it supposed to be a forwarding place interface? If the later, shouldn't it be connected to the VFP VM and not the VCP VM (assuming you are trying to access the control plane over an in-band/forwarding plane interface)? Cheers, James. _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp