Junos Fusion is not supported when hyper-mode is enabled.
-----Original Message----- From: juniper-nsp <juniper-nsp-boun...@puck.nether.net> On Behalf Of Franz Georg Köhler Sent: 07 March 2019 12:46 To: juniper-nsp@puck.nether.net Subject: Re: [j-nsp] Hyper Mode on MX On Thu, Mar 07, 2019 at 12:31:48PM +0100, Olivier Benghozi <olivier.bengh...@wifirst.fr> wrote: > By the way HyperMode is only useful if you expect some very high > throughput with very small packets (none of the MPCs are linerate > using very small packets, but HyperMode brings it closer). Thanks. While we actually don't need that performance really I was wondering if would be a good idea to enable it on new installations preventively. * Padding of Ethernet frames with VLAN. Isn't that a very basic functionality and would break ethernet switching? * Node Virtualization This is Junos Node Slicing? Best regards, Franz Georg Köhler _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp