> Hello, > > I did an issu upgrade on an MX240 with dual routing engines, going > from 15.1R6 to 17.4R2, and I had reviewed the fine manuals particularly > concerning advance steps to ensure nonstop routing and so forth. But > during the upgrade (near the very end), the router did offline my MPC 3D > 16x 10GE, resulting in loss of routing for 5 minutes. According to > juniper in their docs that state that: > > "Unified ISSU is supported with Junos OS Release 17.4R1 for MX Series > routers with MPC-3D-16XGE-SFPP"
I think that might be a misunderstanding. Shouldnt it read "is supported starting with Junos Release 17.4R1"? (That would make sense since some of the cards listed on that paragraph, e.g. MPC7EQ-MRATE-RB, were only supported since JunOS 16+) Because then it would be clear - since you are coming from 15.1R6 this release wouldnt support it and jumping to 17.4R2 would cause the MPC reboot. -Jonas _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp