I recommend you do not use VC at all, and instead use ESI-LAG for the server-facing links.
On Mon, Oct 04, 2021 at 11:43:23AM +0000, Giovanni Bellac via juniper-nsp wrote: > Date: Mon, 4 Oct 2021 11:43:23 +0000 (UTC) > From: Giovanni Bellac <giovannib1...@ymail.com> > To: "juniper-nsp@puck.nether.net" <juniper-nsp@puck.nether.net> > Subject: QFX VC as part of EVPN - redundancy not working > Return-Path: <giovannib1...@ymail.com> > > Hi all, > I am using a QFX5100 2-member-VC as a L2 gateway in a centrally routed > EVPN/VXLAN setup. It seems that the VC redundancy does not work in this > configuration properly. For test purposes I am promoting the backup-RE as > master-RE and afterwards restarting the old master-RE (now backup-RE). While > restarting the backup-RE member the connection to the servers is always lost. > The servers are connected to both members via LACP. > I have tried several JunOS versions (21.1.R1, 20.4R2-S2, 20.2R2-S3, > 19.4R3-S3) but the results are always the same. > > Any suggestions to get this work as intended? > Kind regardsGiovanni _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp