https://bugs.kde.org/show_bug.cgi?id=526119

[email protected] changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |[email protected]

--- Comment #1 from [email protected] ---
I can reproduce this on the same Plasma, Frameworks, Qt versions: the Meta+P
OSD always appears on the output that sits at the top-left of the screen layout
(position 0,0), regardless of which output is set as primary.

Setup: desktop PC, Wayland session, AMD Ryzen 7 5700G (integrated Radeon
graphics, amdgpu).

- Monitor on DisplayPort (DP-1), 2560x1440, priority 1 (primary, confirmed with
kscreen-doctor -o)
- Projector on HDMI (HDMI-A-1), 1920x1080, priority 2

Results:
- Projector placed left of or above the monitor →OSD appears on the projector
- Projector placed right of or below the monitor → OSD appears on the primary
monitor
- Mouse cursor position and the focused window make no difference

Operating System: Manjaro Linux
KDE Plasma Version: 6.7.5
KDE Frameworks Version: 6.30.0
Qt Version: 6.11.2
Kernel Version: 6.18.55-1-MANJARO (64-bit)
Graphics Platform: Wayland
Processors: 16 × AMD Ryzen 7 5700G with Radeon Graphics
Graphics Processor: AMD Radeon Graphics

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to