https://bugs.kde.org/show_bug.cgi?id=528956
Bug ID: 528956
Summary: KWin fails to initialize displays: monitor gets no
signal, error "Failed to find a working output layer
configuration: EACCESS"
Classification: Plasma
Product: kwin
Version First git master
Reported In:
Platform: KDE Linux
OS: Linux
Status: REPORTED
Severity: major
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
Target Milestone: ---
DESCRIPTION
Some (but not all) users report that on KDE Linux 2026-11-12 02:54 and later
images, their displays fail to initalize and show "No signal".
See: https://discuss.kde.org/t/monitor-reports-no-signal/51796
STEPS TO REPRODUCE
1. Have a relevant hardware configuration (see notes below)
2. Boot into a KDE Linux image from 2026-11-12 02:54 or later
OBSERVED RESULT
Plasma should start up normally and displays to the connected monitors
EXPECTED RESULT
Monitors receive no signal. Journal shows an error "Failed to find a working
output layer configuration: EACCESS".
(See for example the logs at
https://discuss.kde.org/t/monitor-reports-no-signal/51796/14)
SOFTWARE/OS VERSIONS
Operating System: KDE Linux (2026-11-12 02:54 or later)
KDE Plasma Version: 6.8.80 (i.e. git master)
KDE Frameworks Version: 6.33.0
Qt Version: 6.12.0
ADDITIONAL INFORMATION
The previous KDE Linux image (2026-11-09 02:54) does not show this issue.
Between that "good" image and the "bad" image, there has been no change in the
version of the kernel, or linux-firmware, or mesa.
KDE Linux uses the git-master version of Plasma components, so it could be that
changes merged into git master between 2026-11-09 and 2026-11-12 are
responsible.
Users so far have reported issues using an Intel Xeon E3-1200 iGPU, and an AMD
RX 6700 (or similar GPU). All of them use HDMI monitors (in some cases with a
DP monitor also connected).
I myself can't replicate it on an Nvidia GPU with a mixture of DP and HDMI
monitors.
--
You are receiving this mail because:
You are watching all bug changes.