https://bugs.kde.org/show_bug.cgi?id=375905

--- Comment #2 from Ryokun <renaudpi...@free.fr> ---
Created attachment 105471
  --> https://bugs.kde.org/attachment.cgi?id=105471&action=edit
terminal log

Hi,

The bug is no more :)

I attached the same log as the bug 375908. I made it before updating my Huion
tablet drivers. You can clearly see that the pressure informations are sent 2
times with totally different values (by example: lines 4773-4774: prs: 0.323232
and prs: 0.160784 for the same x-y coordinates).
On another computer, the same pressure informations where really near one
another, so I updated my tablet drivers and now it works as it should ! (note
that I already updated them before posting this bug, but it still didn't work
then). Maybe the Huion driver had this behavior only on Retina displays ? I
don't hnow....

I still think it worked in other applications because they manage event
coalescing differently than Krita (in other words, they only interpret the
highest pressure value).
But Krita is not wrong on this so don't change anything. Now that Huion
corrected this problem, you can close this bug.
Many thanks.

-- 
You are receiving this mail because:
You are watching all bug changes.

Reply via email to