https://bugs.kde.org/show_bug.cgi?id=445205

            Bug ID: 445205
           Summary: Using the systray icons menu messes up the input
                    methods
           Product: plasmashell
           Version: 5.23.0
          Platform: Debian testing
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: System Tray
          Assignee: plasma-b...@kde.org
          Reporter: a...@laxu.de
                CC: mate...@gmail.com
  Target Milestone: 1.0

SUMMARY
Since the upgrade to Plasma 5.23.0 (KF 5.86.0, Qt 5.15.2), using the menu of
tray icons causes chaos with the input methods.
Possibly it is only mouse input, but that's hard to say as it literally causes
chaos.

The first time I click, I can use the menu of some tray icon (here mostly
cantata and xpra) as usual. The second or third time, the menu does not work,
but afterward moving the mouse causes a lot of random clicks in random windows,
until I change to the Linux console, run "killall plasmashell", switch back and
then restart plasmashell.

Things that may be relevant:
- I use a vertical panel on the left side of the screen and the tray area is at
bottom
- I use focus follows the mouse (which probably explains why it seems like
random windows are target of the random clicks)

I do not know where to start debugging the issue. The only thing I can say is,
that it started with new plasma/kf packages in Debian testing and since then
constantly happens.
If there were major changes in plasma/panels/systray between the previous
version and 5.23.0, it would be help to know where to start looking for what
may cause the issue.

-- 