https://bugs.kde.org/show_bug.cgi?id=456385

Nate Graham <n...@kde.org> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
          Component|Panel                       |Multi-screen support
                 CC|                            |aleix...@kde.org,
                   |                            |notm...@gmail.com

--- Comment #18 from Nate Graham <n...@kde.org> ---
All your panels seem to have sane thickness values:


[PlasmaViews][Panel 1][Defaults]
thickness=32

[PlasmaViews][Panel 1][Horizontal0]
thickness=30

[PlasmaViews][Panel 1][Horizontal1024]
length=674
thickness=34

[PlasmaViews][Panel 1][Horizontal1280]
length=646
thickness=32

[PlasmaViews][Panel 1][Horizontal1920]
length=1001
thickness=32

[PlasmaViews][Panel 1][Horizontal2048]
thickness=30


What may be happening is that a race condition causes a panel that's on an
inactive input to get inappropriately queried and then it returns an invalid
number. Needs investigation by a multiscreen expert; CCing Marco.

-- 