https://bugs.kde.org/show_bug.cgi?id=475539
Bug ID: 475539 Summary: Turning off floating Panel mode and then turning it back on makes panel float even if touched until plasmashell is restarted Classification: Plasma Product: plasmashell Version: 5.27.8 Platform: Other OS: Linux Status: REPORTED Keywords: qt6, regression Severity: normal Priority: NOR Component: Panel Assignee: plasma-b...@kde.org Reporter: n...@kde.org CC: niccolo.venera...@gmail.com Target Milestone: 1.0 Current git master Plasma 6 on Wayland. STEPS TO REPRODUCE 1. Make your Panel be floating, if it wasn't already 2. Maximize a window 3. Restart plasmashell to ensure a clean state 4. Right-click on Panel > Enter Edit Mode 5. Click "More Settings" 6. Click "Attached" 7. Click "Floating" OBSERVED RESULT The panel has become floating again, despite there being a maximized window EXPECTED RESULT The panel remains de-floated ADDITIONAL INFORMATION Restarting plasmashell again at this point causes the panel to de-float as expected -- You are receiving this mail because: You are watching all bug changes.