https://bugs.kde.org/show_bug.cgi?id=480805
Bug ID: 480805 Summary: Battery charge graph shows no data when charge reaches 100 % Classification: Applications Product: kinfocenter Version: 5.27.10 Platform: Arch Linux OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: general Assignee: plasma-b...@kde.org Reporter: dev-...@felsenfleischer.de CC: sit...@kde.org Target Milestone: --- Created attachment 165510 --> https://bugs.kde.org/attachment.cgi?id=165510&action=edit Screenshot of the two battery graphs at the same time SUMMARY During a seldomly done full charge of the battery I noticed that the charge graph stops collecting data when the battery reached around 99 %. The battery actually kept on charging for a good while longer because it is miscalibrated. This can also be observed in the power graph. STEPS TO REPRODUCE Charge the battery to the top. OBSERVED RESULT The graph has a gap when it reaches around 99 %. EXPECTED RESULT The graph should be continuous. SOFTWARE/OS VERSIONS Operating System: Arch Linux KDE Plasma Version: 5.27.10 KDE Frameworks Version: 5.114.0 Qt Version: 5.15.12 Kernel Version: 6.7.3-arch1-1 (64-bit) Graphics Platform: X11 -- You are receiving this mail because: You are watching all bug changes.