https://bugs.kde.org/show_bug.cgi?id=494896
Bug ID: 494896
Summary: Z-order of plasmoid tooltips below windows
Classification: Plasma
Product: plasmashell
Version: master
Platform: Other
OS: Linux
Status: REPORTED
Severity: normal
Priority: NOR
Component: general
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected]
Target Milestone: 1.0
SUMMARY
I am using Plasma with BSPWM as my window manager and the z-order of plasmoid
tooltips is wrong: they are beneath my windows. This used to work fine on
Plasma 5, but it has been broken since Plasma 6. It only affects hovering,
clicking the plasmoid works as expected.
STEPS TO REPRODUCE
1. Use another window manager (BSPWM) in my case
2. Create a Plasma panel, e.g. on the top edge of the screen
3. Add a plasmoid to the panel (e.g. the volume control widget)
4. Open application window (e.g. Dolphin)
5. Hover the mouse over the plasmoid
If the window is transparent you can make out the tooltip of the plasmoid, so
it is definitely being rendered, it's just covered by the application window. I
would like to attach a screenshot, but the tooltip vanishes every time
Spectacle takes a snapshot.
OBSERVED RESULT
EXPECTED RESULT
The tooltip should be rendered above any application windows, just like what
you get when you click the plasmoid.
SOFTWARE/OS VERSIONS
Linux/KDE Plasma: Void Linux
KDE Plasma Version: 6.20
KDE Frameworks Version: 6.6.0
Qt Version: 6.7.2
--
You are receiving this mail because: