Issue #6577 has been reported by Daniel Crawl.

----------------------------------------
Bug #6577: infinite loop resolving port width
https://projects.ecoinformatics.org/ecoinfo/issues/6577

* Author: Daniel Crawl
* Status: New
* Priority: Normal
* Assignee: 
* Category: 
* Target version: 2.5.0
* Bugzilla-Id: 
----------------------------------------
There are several actors whose output port is set to multiport. When this port 
is connected to a multiport input port, an error occurs when the workflow 
executes saying that the default port width could not be determined. The error 
message says that one way to fix this is call setDefaultPortWidth(1). This 
works if the output port is connected to only one port, but if the output port 
is connected to more ports, an infinite loop occurs during preinitialize(). I'm 
attaching an example workflow.


-- 