On Mon, Jun 9, 2014 at 10:02 PM, Wayne Stambaugh <[email protected]> wrote:
> I'm sure you already thought of this but making X2 gerbers a plot option > solves both problems and it shouldn't be too difficult to implement. > It's probably safer this way just in case someone has a board vendor > that cannot handle the X2 gerbers. > > I have just submitted a patch that does the above. On Mon, Jun 09, 2014 at 08:01:47PM +0200, jp charras wrote: > > Drill files as plots are cute but nothing extraordinary; they could have > > their use but I don't see them replacing excellon or s&m tapes... > > Excellon works fine, no need to replace this format. An advantage would be that the new Gerber specification allows to indicate per hole: - whether it is plated or non-plated - what layer sets the hole goes through (for blind & buried vias) So it makes the drill report mostly redundant. Regards, Thiadmer Riemersma