Hi Jeff, Spice netlist exporter outputs a single line for each part (including multi-unit ones), meaning you have 1:1 part to model relation. I have not checked, but I suppose that in case of divergent field values for each unit, the first unit has the priority.
Speaking of tubes, I have never seen heater models for Spice. Normally it is assumed that you have your devices warm and glowing, but perhaps there are exceptions. Cheers, Orson On 04/25/2018 06:11 PM, Jeff Young wrote: > Hi Orson, > > How does the SPICE integration work with multi-unit parts? If I have a valve > with two triode units and a heater unit, do I have a single SPICE model, or > are the heaters modelled separately from the triodes (or perhaps even not at > all)? > > Thanks, > Jeff. > _______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : kicad-developers@lists.launchpad.net Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp