Hi

The Electrical Rules Check in EESCHEMA doesn't produce any errors,
even though I haven't placed a PWR_FLAG on the power supply
connections. The problem seems to be with pcbnew. Any ideas?

Chris



--- In [email protected], "Danilo Uccelli" <[EMAIL PROTECTED]> wrote:
>
> Hi,
> 
> Is the Electrical Rules Check in EESCHEMA give you some errors ?
> Have you put a PWR_FLAG on GND and one in VCC on your schematic ?
> 
> Danilo Uccelli
> 
> 2006/8/10, c.cawe <[EMAIL PROTECTED]>:
> > Hello. I'm having some problems with the DRC control in pcbnew.
When I click on "Test DRC" it finds no errors. However, when I click
on "List Unconn" it lists numerous unconnected pads. From the PCB
layout and Gerber files it appears as though they are connected
properly. The majority of the listed pads are connected directly to a
ground/power plane or through a via - does pcbnew always recognise
these type of pad connections as being "unconnected"? If so would it
be safe to nassume from the Gerber files that the PCB is ok?

Many thanks

Chris






Please read the Kicad FAQ in the group files section before posting your 
question.
Please post your bug reports here. They will be picked up by the creator of 
Kicad.
Please contribute your symbols/modules to the library folder in the group files 
section.
For building Kicad from source and other development questions visit the 
kicad-devel group at http://groups.yahoo.com/group/kicad-devel 
Yahoo! Groups Links

<*> To visit your group on the web, go to:
    http://groups.yahoo.com/group/kicad-users/

<*> To unsubscribe from this group, send an email to:
    [EMAIL PROTECTED]

<*> Your use of Yahoo! Groups is subject to:
    http://docs.yahoo.com/info/terms/
 



Reply via email to