dave a écrit :
> jean-pierre charras wrote:
>
>   
>> dave a écrit :
>>
>>     
>>> Dan Andersson wrote:
>>>  
>>>
>>>       
>>>> On Sunday 25 November 2007 07:15:05 dave wrote:
>>>>
>>>>    
>>>>
>>>>         
>>>>> what am i doing wrong?
>>>>>
>>>>> i drew up a schematic and made a netlist and started to layout the board. 
>>>>> i
>>>>> found an error and when i went back to correct it and then make a new
>>>>> netlist the program changed several part numbers..  so then it gave me an
>>>>> error when it read the new netlist in the pcb layout program.
>>>>>
>>>>> it is driving me nuts!!!
>>>>>
>>>>> am i doing something wrong or is there a problem with the program?
>>>>>
>>>>>
>>>>> thanks for the help
>>>>>
>>>>> dave.
>>>>>      
>>>>>           
>>>> The pcb layout does not replace or change modules as default, you need to 
>>>> tick 
>>>> the correct box for that in the net list read window.
>>>>
>>>> //Dan
>>>>    
>>>>         
>>> yes. this i understand.  the problem is that in the eeschema program when i 
>>> make changes and 
>>> a make new netlist several part numbers ie: U12, U13, U14 are changed to 
>>> U055, U056, U057 in the 
>>> eeschema drawing and in the net list and then in the pcb drawing and that 
>>> causes the traces that 
>>> were on the old parts to have no connections?
>>>
>>> something is wrong somewhere, but is it something i am doing or is there a 
>>> bug in the program?
>>>  
>>>       
>> When eeschema renums components like U055, U056, U057 ... this is 
>> because these components are flagged as "power symbols"
>> Only power symbols (like VCC, GND ...) must be flagged  "power 
>> component" because they are not really "components", they are special 
>> symbols
>>
>>     
>
> where are the power symbols on the component.  it is something that i put 
> there.
> i don't think so.  i did not have a reason as they are just more of the 
> component on the sheet.
>
> if they are marked how do i get rid of the mark?
>
>   
In Libedit, "edit component properties" dialog, uncheck "power symbol" 
option


-- 
Jean-Pierre CHARRAS
Maître de conférences
Directeur d'études 2ieme année.
Génie Electrique et Informatique Industrielle 2
Institut Universitaire de Technologie 1 de Grenoble
BP 67, 38402 St Martin d'Heres Cedex

Recherche :
 Grenoble Image Parole Signal Automatique (GIPSA - INPG)
46, Avenue Félix Viallet
38031 Grenoble Cedex

Reply via email to