Boris Barbour a écrit :
>
>
>
> Hi,
>
>
> Is it possible to join a track to a net without starting drawing on 
> the net in question? In other words, if I start tracing in the middle 
> of nowhere, the track is assigned to Net:0/noname. It is then 
> impossible to join it to another net with DRC on (I get the 
> ErrType(16) of the subject); with DRC off I can make the join, but the 
> track retains its null net and will evermore generate DRC errors.
>
>
> Is there a way to induce Kicad to change the net name once the join is 
> made, either automatically or manually?
>
>
> In case you are wondering why I should want to do this, the issue 
> arises most often when drawing guarding and shielding traces. I've 
> managed to work around the problem so far, but not without difficulty.
>
>
> Best wishes
>
>
> Boris

Just open netlist dialog and run "Rebuild Board Connectivity"
-- 
Jean-Pierre CHARRAS
Maître de conférences
Directeur d'études 2ieme année.
Génie Electrique et Informatique Industrielle 2
Institut Universitaire de Technologie 1 de Grenoble
BP 67, 38402 St Martin d'Heres Cedex

Recherche :
Grenoble Image Parole Signal Automatique (GIPSA - INPG)
Grenoble France

Reply via email to