Hi,
I use Kubuntu, but I always install Kicad this way:

** Under Linux:

You must be "root".
goto /usr/local

Untar kicad.tgz : tar zxvf kicad.tgz

The main program is /usr/local/kicad/bin/kicad
If you use KDE, users can copy the shortcut /usr/local/kicad/bin/kicad.desktop
in <user home directory>/Desktop and use it to run kicad.


In the example, kikad.tgz stands for one of these files:
kicad-2009-02-16-final-CENTOS_4.4.tgz
kicad-2009-02-16-final-UBUNTU_8.10.tgz

Good luck,

Pedro.
> Yes, I know there is a new verion, but I don't know how to install it - the 
old version comes with the repositories in my distro PCLinuxOS.
> I think the new version includes the zones in the DRC control (my version 
does not) , then it is easy to discover if this bug appears also in the new 
version ( if I just do an DRC test after the zones are made).
> 
> Jens
> 
> 
> --- In kicad-users@yahoogroups.com, Pedro Martin <pki...@...> wrote:
> >
> > Hi,
> > 
> > I have not studied your problem, but some zone bugs were fixed in later 
> > versions. Try 2009-02-16 version.
> > 
> > Pedro.
> > 
> > > I've just encountered a very strange thing when generating a Zone in 
PCBnew. 
> > [version: "** PCBNEW  (sept 1992 .. 2006) **Build Version:PCBNEW 
> > (2007-07-09) - Unicode version"]
> > > 
> > > I have choosen the finest pitch (grid: 0.120 mm) and Zone clearance 
0.444 
> > mm. I had done first the GND zone, and next I was about to do the VCC 
zone. 
> > But it doesn't only generate the ordinary zone, but it also makes some 
very 
> > broad tracks that in some places override the zone clearance space, and in 
> > one spot actually shortcuts VCC to the GND zone.
> > > (I doscovered this after measuring zero ohms on the final product!)
> > > 
> > > The faulty tracks belongs to the generated zone - they are not editable, 
but 
> > disappear if I choose to delete the zone. 
> > > 
> > > How can I avoid this to happen?
> > > 
> > > I uploaded some screenshots where you can see the PCB with and without 
the 
> > VCC Zone so you can understand what I mean.
> > > 
> > > (pics: zone1.jpg, zone2.jpg, zone3.jpg and zone4.jpg at 
> > 
http://groups.yahoo.com/group/kicad-users/photos/album/1407660911/pic/list )
> > > 
> > >
> >
> 
> 
>

Reply via email to