On Thu, 2007-07-12 at 13:33 +0800, Dong, Eddie wrote: > Here is the update with adding HLT cap.
Thats a good start, but you probably need to make the decision to use the halt predicated on a halt-specific boolean set by userspace in order to actually function as we've discussed. This is in contrast to overloading the decision with the presence of the in-kernel PIC. A capability indicator without a way to turn it on/off is fairly useless, IMHO. Conversely I don't think its a big deal to just skip the predicate all together since your version of the patches wont cause as severe of an issue as we had in hybrid mode. So I would say either make the full conversion or drop the CAP altogether. -Greg ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/ _______________________________________________ kvm-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/kvm-devel