At 10:51 AM 6/9/2012, you wrote:
I need clear answer for this condition

in our country new Panasonic Pabx   Kx-tda100d  with 7 slots demond
kxtda-200 & kxtda 100 is old model



if customer wants 144 extension with  16 loct no    want  disa +opb card
we arrange   24 extension card X  6 =  144  extension
on last slot we use 2 card marge  as 8 loct main & daughter card

The customer could have 176 phones until you made 120 of the SLT's. YOU HAVE TO READ THE EFFING MANUAL! Your first request in the other forum and the follow up got polite answers. The first response here, not so much. A TDA-100D still only has a place for a 128 unit power supply, the fact that is clearly explained in the provisioning and power requirements section of the 100D manual. You can have beyond the 128 phones if you use IP sets, see the hardware section. There is no 24-port digital card and it doesn't matter because you can't put more than 8 power units beyond the 120 you already used for the SLT's.

Sorry if this is an English manual link, but find one in your native language then you can understand it better.

Carl


        -





if we use l type pwer supply 144 extesnion working or not


because on s power supply only 120 extension work after check
last 5 card is not show dial tone one company told us 144 extension work on this pabx
with same this configration



L type power supply no avaliable on my stock if I arrange than teste on this unit
want time


 any help  on this topis pls rpely

Mohammad Younus shaikh
_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt

Age improves with wine
_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt

Reply via email to