At 10:51 AM 6/9/2012, you wrote:
I need clear answer for this condition
in our country new Panasonic Pabx Kx-tda100d with 7 slots demond
kxtda-200 & kxtda 100 is old model
if customer wants 144 extension with 16 loct no want disa +opb card
we arrange 24 extension card X 6 = 144 extension
on last slot we use 2 card marge as 8 loct main & daughter card
The customer could have 176 phones until you made 120 of the
SLT's. YOU HAVE TO READ THE EFFING MANUAL! Your first request in
the other forum and the follow up got polite answers. The first
response here, not so much. A TDA-100D still only has a place for a
128 unit power supply, the fact that is clearly explained in the
provisioning and power requirements section of the 100D manual. You
can have beyond the 128 phones if you use IP sets, see the hardware
section. There is no 24-port digital card and it doesn't matter
because you can't put more than 8 power units beyond the 120 you
already used for the SLT's.
Sorry if this is an English manual link, but find one in your native
language then you can understand it better.
Carl
-
if we use l type pwer supply 144 extesnion working or not
because on s power supply only 120 extension work after check
last 5 card is not show dial tone one company told us 144
extension work on this pabx
with same this configration
L type power supply no avaliable on my stock if I arrange
than teste on this unit
want time
any help on this topis pls rpely
Mohammad Younus shaikh
_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
Age improves with wine