I am going to build  a couple of T5240's with LDOM 1.2 s/w  in an as redundant 
config as possible. 

   I Have   two  Emulex LP11000s  cards  with Sun Microcode and   an additional 
 QuadGIG eth card in the systems.  

   I have Split  the PCI  bus and  created the secondary I/O  domain. 
   I have given the Scondary  I/O domain a SAN card and the additional quad gig 
card. 
  I have connected both FC cards to the SAN  and both set of quad Gig cards to 
the Cisco  backbone. 
   I have  tried booting the secondary I/O Domain directly  from the SAN using 
its local  FC card. 
   THis doesnt work and I belive the Documentation also says that its not 
supported. 

   I Can boot the secondary  I/O domain off the  primary domains  FC card  via 
its VDS switch of course. 
  I plan to set up  Virtual disk Multipathing  using the  mpgroup  feature of 
the VDS. 

Now to the question: 

    IF I boot the Secondary I/O domain  of the Control domains FC-Card  and at 
some later
  point in time the Control domains SAN connection  fails ! 

    Will that  crash  the secondary domain as its boot disk  will disappear  ? 

   WIll this as an additional  effect  break the secondary I/O domains  VDS to 
the  Guest 
domains , so that  the guest domains  will  loose  both the  disk paths  
configured 
 in the  vds mpgroup ? 


   Would it be a better solution to  boot the secondary I/O  domain  from the  
same 
   T5240  Local  SAS disks  as the  the primary domain uses ? 

   Regards 

   //Lars
-- 
This message posted from opensolaris.org

Reply via email to