On Wednesday 19 December 2007 16:36:40 Mats Erik Andersson wrote: > Hello all, > > would it be a serious security flaw to arrange > that at least the bootfloppy provides a serial > console in the form the image is delivered from > "factory"? The neccesary changes are easy enough: > > 1) an addition of "console=ttyS0,19200n8 console=tty0" > to the file syslinux.cfg > > and > > 2) removal of one hash mark in front of "ttyS0" in > /etc/inittab. > > Such serial access would very much lessen the labour > to configure a recycled, but functional machine. > > Regards > > Mats Erik Andersson
Hi Mats; I talked with Eric Spakman and he remembered, why we removed it from the image a few years ago: On machines with no serial console attached the screen was flooded with messages about init respawning too fast about every five seconds. And I think, his memory is correct in that case. So we refuse to change it back -. I hope you understand happy new year to you all kp ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2005. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ ------------------------------------------------------------------------ leaf-user mailing list: leaf-user@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/leaf-user Support Request -- http://leaf-project.org/