Jorn Eriksen wrote:
> I got a few ALIX unit here and apart from the network drivers, all seams to
> work.  The Watchdog don't work as expected (ref to Eric post earlier).
I can confirm as well that the box works fine (minus the watchdog - no 
surprise there).
I simply took an image that was made for a WRAP box, switched the 
network driver modules and everything seems to work.  I haven't had time 
for some serious testing yet - so I can't say if USB will work, or what 
kind of performance figures one will get out of it. It boots 
significantly faster than a WRAP - that's all I can say right now.

> The network should work with the Via Rhine driver but I have not ben able to
> get it to work though.....
Could it be that you missed a dependency of the via-rhine module? 
via-rhine needs crc32 and mii to work

firewall# lsmod | grep rhine
via-rhine              10628   2
mii                     1820   0 [via-rhine]
crc32                   2620   0 [via-rhine]


You should see errors about "unresolved symbols" when insmodding the 
via-rhine module.