> Hm, IMO the advantage of the initial smear approach (24 hours before the
> leap second) is that smearing is finished as soon as the leap second has
> occurred, so the beginning of the next UTC day /hour / minute is accurate.

Martin,

I suspect your idea only works in cases when the time server is instantaneously 
jamming time to a stateless client. But there is often some level of filtering 
and so the client will necessarily lag the server. In this case the client will 
not have accurate UTC until many time constants after midnight.

/tvb

_______________________________________________
LEAPSECS mailing list
LEAPSECS@leapsecond.com
https://pairlist6.pair.net/mailman/listinfo/leapsecs

Reply via email to