On Fri, Sep 28, 2012 at 12:54:07AM -0400, Justin Ruggles wrote:
> --- a/doc/filters.texi
> +++ b/doc/filters.texi
> @@ -322,30 +322,49 @@ conversion.
>
> -The filter accepts exactly one parameter @var{vol}, which expresses
> -how the audio volume will be increased or decresed.
> +The filter accepts the following named parameters:
> +@table @option
> +
> +@item volume
> +Expresses how the audio volume will be increased or decreased.
>
> Output values are clipped to the maximum value.
>
> -If @var{vol} is expressed as a decimal number, and the output audio
> +If @var{volume} is expressed as a decimal number, and the output audio
>
> -If @var{vol} is expressed as a decimal number followed by the string
> +If @var{volume} is expressed as a decimal number followed by the string
I'd do s/expressed/given/ here to avoid repeating "expressed",
which was used above.
> +@table @option
> +@item fixed
> +8-bit fixed-point. Limits input sample format to U8, S16, and S32.
> +@item float
> +32-bit floating-point. Limits input sample format to FLT. (default)
> +@item double
> +64-bit floating-point. Limits input sample format to DBL.
> +@end table
I'd replace the periods by semicolons, i.e.
8-bit fixed-point; limits input sample format to U8, S16, and S32.
which makes it read more natural to me.
Don't bother sending a fresh patch for these changes.
Diego
_______________________________________________
libav-devel mailing list
[email protected]
https://lists.libav.org/mailman/listinfo/libav-devel