3973 seems very low for IOCP.  Perhaps because you're testing all on one box?
 
I've had IOCP servers streaming 500 bytes of data once a second to 15k+ concurrent/persistent connections.

 
On 10/31/06, Toby Douglass <[EMAIL PROTECTED]> wrote:
First testing using my real IP address, connecting to myself, gives a
perfectly repeatable 3973 sockets before failure.

This is with MaxUserPort set to 20000 (decimal), although I've not
rebooted...

I have 512mb, running w2k sp4.

Anyone interested in running the test app on their machine?

Same binary is client and server;

Do "test s" first to start the server, then "test c" in another window
to run the client.

Client will display number of connected sockets, as it continually
connects.  Client will eventually fail and print message why.