>>>>> "Mikael" == Mikael Krus <[email protected]> writes:

    Mikael>   Hi, I have a FT2232H chip where I intend to use interface_B in
    Mikael> MPSSE mode.  If I use ftdi_set_interface() specifying
    Mikael> INTERFACE_B, later on when closing the device I always get an
    Mikael> error (-1) but with error string set to: all fine.

    Mikael> This only happens with INTERFACE_B not INTERFACE_A.

    Mikael> Why does this happen?  Am I misunderstanding something?

You need a context for every interface

Bye
-- 
Uwe Bonnes                [email protected]