Hello, For a user programm to determine if a connected FTDI device has the 60 MHz clock option (e.g. FT2232H) or not (e.g. FT2232D), I only see on way: - Send the Disable Clk Divide by 5 command (0x8a) - Observe if the command is accepted or not.
In the case the command succeeds, nothing will happen. A FT2232D will not understand the command and so will send "BAD COMMAND" (0xfa) followed by the command (0x8a). In the case of a FT2232D, a read(2) would succeed. However on a device that knows the command, no output is generated. Some read will hang until our 5000 ms timeout is elapsed and make this approach user unfriendly. Two things could help in this situation: - either have a way to query the device via libftdi is there is something pending in the read buffer - or have a way to set the read timeout via libftdi. I neither see any of those two ways. Do I miss something? A workaround sees to be: send DIS_DIV_5 send GET_BITS_LOW send GET_BITS_LOW read two byte if bytes read are 0xfa DIS_DIV_5 device has slwo clock read two bytes else device has 60 MHz clock. Some BAD_COMMAND definition also misses in out headers. Bye -- Uwe Bonnes [email protected] Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt --------- Tel. 06151 1623569 ------- Fax. 06151 1623305 --------- -- libftdi - see http://www.intra2net.com/en/developer/libftdi for details. To unsubscribe send a mail to [email protected]