Hi. I got 2 power supplies. But if someone by mistake pull the power cables , is that mean
That the services will not failover ?? Regards Shalom. On Wed, Mar 3, 2010 at 1:15 AM, Georgi Stanojevski <gli...@gmail.com> wrote: > On Tue, Mar 2, 2010 at 6:17 PM, שלום קלמר <skle...@gmail.com> wrote: > >> >> The only test which failed was - pulling out power cable from one node. >> >> The other system try in loop fencing the failed node & services not >> relocated. >> >> >> > As I understand this is by design. > > When you pull out the power cables you shutdown the fencing device on that > node and the remaining node can't successfully fence it. > > The nodes should have redundant power supplies, to avoid single point of > failure. > > -- > Glisha > http:// > > -- > Linux-cluster mailing list > Linux-cluster@redhat.com > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list Linux-cluster@redhat.com https://www.redhat.com/mailman/listinfo/linux-cluster