That won't work then since pulling the power cable effectively disables the drac port. You need some out of band controller for that type of fencing to work. I use APC units, others will prefer different units. It's the same problem as with an iLO. Actually, you can get into the same problem if your power controllers and nodes are in different racks and you have a rack level failure.
Regards Corey On Wed, Mar 3, 2010 at 11:05 AM, שלום קלמר <[email protected]> wrote: > Hi. > > I am runnig fence_ipmilan on iDRAC6. > > Regards > > Shalom > > On Wed, Mar 3, 2010 at 6:22 AM, Rajagopal Swaminathan < > [email protected]> wrote: > >> Greetings, >> >> On Tue, Mar 2, 2010 at 10:40 PM, שלום קלמר <[email protected]> wrote: >> > Hello. >> > >> > Everything is working fine. We did some failover tests, all tests passed >> ( >> > nic , fiber , reboot ). >> > >> > The only test which failed was - pulling out power cable from one node. >> > >> >> >> How do you do the fencing? in-band (ILO, RSA, ALOM, DRAC) or >> out-of-band (Power fencing) >> >> Regards, >> >> Rajagopal >> >> -- >> Linux-cluster mailing list >> [email protected] >> https://www.redhat.com/mailman/listinfo/linux-cluster >> > > > -- > Linux-cluster mailing list > [email protected] > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list [email protected] https://www.redhat.com/mailman/listinfo/linux-cluster