Hi Marek, Can we give this option in cluster.conf file for bladecenter fencing device or method
For IPMI, fencing is there similar option? On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac <mg...@redhat.com> wrote: > Hi, > > > On 04/27/2011 10:29 AM, Parvez Shaikh wrote: > >> Hi all, >> >> I am using RHCS on IBM bladecenter with blade center fencing. I plugged >> out a blade from blade center chassis slot and was hoping that failover to >> occur. However when I did so, I get following message - >> >> fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain >> correct plug status or plug is not available >> fenced[10240]: fence "blade1" failed >> >> Is this supported that if I plug out blade from its slot, then failover >> occur without manual intervention? If so, which fencing must I use? >> > > You can use option missing_as_off (or --missing-as-off at command line) > which returns off even in a case when blade does not exists. > > m, > -- > Linux-cluster mailing list > Linux-cluster@redhat.com > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list Linux-cluster@redhat.com https://www.redhat.com/mailman/listinfo/linux-cluster