Hi Marek,

Can we give this option in cluster.conf file for bladecenter fencing device
or method

For IPMI, fencing is there similar option?


On Fri, Apr 29, 2011 at 1:38 PM, Marek Grac <mg...@redhat.com> wrote:

> Hi,
>
>
> On 04/27/2011 10:29 AM, Parvez Shaikh wrote:
>
>> Hi all,
>>
>> I am using RHCS on IBM bladecenter with blade center fencing. I plugged
>> out a blade from blade center chassis slot and was hoping that failover to
>> occur. However when I did so, I get following message -
>>
>> fenced[10240]: agent "fence_bladecenter" reports: Failed: Unable to obtain
>> correct plug status or plug is not available
>> fenced[10240]: fence "blade1" failed
>>
>> Is this supported that if I plug out blade from its slot, then failover
>> occur without manual intervention? If so, which fencing must I use?
>>
>
> You can use option missing_as_off (or --missing-as-off at command line)
> which returns off even in a case when blade does not exists.
>
> m,
> --
> Linux-cluster mailing list
> Linux-cluster@redhat.com
> https://www.redhat.com/mailman/listinfo/linux-cluster
>
--
Linux-cluster mailing list
Linux-cluster@redhat.com
https://www.redhat.com/mailman/listinfo/linux-cluster

Reply via email to