Hi, I upgraded to Corosync 1.4.2 and cman 6.2.0, but when I add this to my cluster.conf :
<cman expected_votes="1" two_node="1" *transport="udpu"*/> I get (when starting cman) : Starting cman... Relax-NG validity error : Extra element cman in interleave tempfile:20: element cman: Relax-NG validity error : Element cluster failed to validate content Configuration fails to validate Any idea why? Thanks, - Mike [email protected] On Fri, Dec 30, 2011 at 7:32 PM, Andreas Kurz <[email protected]> wrote: > Hello, > > On 12/30/2011 10:16 PM, Michel Nadeau wrote: > > Hi, > > > > We're trying to configure a CMAN cluster with 2 nodes located in 2 > > different datacenters. > > only one of various problems of split-site cluster: how do you plan to > implement reliable fencing? > > > > > The 2 nodes are running Debian 6 and they can access each other on the > > private LAN (using the eth0 interface). > > > > The problem is that the 2 nodes don't have the same subnet and the > > multicast doesn't seem to work: is there any way to make this work? > > since 1.3.0 corosync supports unicasts (UDPU) ... it ships with a nice > example configuration. > > Regards, > Andreas > > -- > Need help with Corosync? > http://www.hastexo.com/now > > > > > Thanks, > > > > - Mike > > [email protected] <mailto:[email protected]> > > > > > > > > -- > > Linux-cluster mailing list > > [email protected] > > https://www.redhat.com/mailman/listinfo/linux-cluster > > > > > -- > Linux-cluster mailing list > [email protected] > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list [email protected] https://www.redhat.com/mailman/listinfo/linux-cluster