On Sat, 13 Mar 1999 15:37:28 +0100, hai scritto:
>My diald config/setting works fine...but after about 60 secound, diald always send
>a signal that brings the connection down :(
>logfile:
>- - -
>Mar 13 15:26:30 flag diald[2960]: Connect script timed out. Killing script.
>Mar 13 15:26:30 flag diald[2960]: new state STOP_DIAL action 0x804f940 timeout 60
>Mar 13 15:26:30 flag diald[2960]: Sending SIGINT to (dis)connect process 2967
>- - -
This log shows that the connection is never estabilished because the connect script
fails.
Check the connect script. Diald can't do anything if that script fails.
>And: Whats the different between accept and keepup?!
A packet that matches an accept rule can bring the link up.
A packet that matches only a keepup rule can't bring the link up, but once the link is
up
it can keep it up (as per timeout settings in standard filter).
Ciao.
--
Giulio