On 4/19/07, Peter Kruse <[EMAIL PROTECTED]> wrote:
Andrew Beekhof wrote:
> then i'm afraid your use of the "dont fence nodes on startup" option
> has come back to haunt you
>
> beosrv-c-1 came up but was not able to find beosrv-c-2 (even though it
> _was_ running) and because of that option beosrv-c-1 just pretended
> beosrv-c-2 wasn't running and happily started activating resources.
>
> remember how we said that option wasn't a good idea :-)

Hm, I don't understand, beosrv-c-2 fenced beosrv-c-1 in order
to take over.  Now you say, that as soon as beosrv-c-1 came back
up again, it should fence beosrv-c-2, because it "thought" it
was not there, but it was there?  How can this happen?

usually an enduring communications failure (be it physical or in our
software) but i'm no expert regarding the membership and
communications layers

But I see a lot of messages like:
Apr 19 09:49:47 beosrv-c-1 heartbeat: [4495]: WARN: Rexmit of seq
3553687 requested. 141 is max.

so _something_ isn't right.

probably worthy of a bug report.


        Peter

_______________________________________________
Linux-HA mailing list
Linux-HA@lists.linux-ha.org
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems

_______________________________________________
Linux-HA mailing list
Linux-HA@lists.linux-ha.org
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems

Reply via email to