How do you configure clvmd?

with cman or with pacemaker?

Il giorno 23 marzo 2012 22:14, William Seligman <[email protected]
> ha scritto:

> On 3/23/12 5:03 PM, emmanuel segura wrote:
>
> > Sorry but i would to know if can show me your /etc/cluster/cluster.conf
>
> Here it is: <http://pastebin.com/GUr0CEgZ>
>
> > Il giorno 23 marzo 2012 21:50, William Seligman <
> [email protected]
> >> ha scritto:
> >
> >> On 3/22/12 2:43 PM, William Seligman wrote:
> >>> On 3/20/12 4:55 PM, Lars Ellenberg wrote:
> >>>> On Fri, Mar 16, 2012 at 05:06:04PM -0400, William Seligman wrote:
> >>>>> On 3/16/12 12:12 PM, William Seligman wrote:
> >>>>>> On 3/16/12 7:02 AM, Andreas Kurz wrote:
> >>>>>>> On 03/15/2012 11:50 PM, William Seligman wrote:
> >>>>>>>> On 3/15/12 6:07 PM, William Seligman wrote:
> >>>>>>>>> On 3/15/12 6:05 PM, William Seligman wrote:
> >>>>>>>>>> On 3/15/12 4:57 PM, emmanuel segura wrote:
> >>>>>>>>>>
> >>>>>>>>>>> we can try to understand what happen when clvm hang
> >>>>>>>>>>>
> >>>>>>>>>>> edit the /etc/lvm/lvm.conf  and change level = 7 in the log
> >> session and
> >>>>>>>>>>> uncomment this line
> >>>>>>>>>>>
> >>>>>>>>>>> file = "/var/log/lvm2.log"
> >>>>>>>>>>
> >>>>>>>>>> Here's the tail end of the file (the original is 1.6M). Because
> >> there no times
> >>>>>>>>>> in the log, it's hard for me to point you to the point where I
> >> crashed the other
> >>>>>>>>>> system. I think (though I'm not sure) that the crash happened
> >> after the last
> >>>>>>>>>> occurrence of
> >>>>>>>>>>
> >>>>>>>>>> cache/lvmcache.c:1484   Wiping internal VG cache
> >>>>>>>>>>
> >>>>>>>>>> Honestly, it looks like a wall of text to me. Does it suggest
> >> anything to you?
> >>>>>>>>>
> >>>>>>>>> Maybe it would help if I included the link to the pastebin where
> I
> >> put the
> >>>>>>>>> output: <http://pastebin.com/8pgW3Muw>
> >>>>>>>>
> >>>>>>>> Could the problem be with lvm+drbd?
> >>>>>>>>
> >>>>>>>> In lvm2.conf, I see this sequence of lines pre-crash:
> >>>>>>>>
> >>>>>>>> device/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:271   /dev/md0: size is 1027968 sectors
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> device/dev-io.c:271   /dev/md0: size is 1027968 sectors
> >>>>>>>> device/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> filters/filter-composite.c:31   Using /dev/md0
> >>>>>>>> device/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> label/label.c:186   /dev/md0: No label detected
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> device/dev-io.c:535   Opened /dev/drbd0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:271   /dev/drbd0: size is 5611549368 sectors
> >>>>>>>> device/dev-io.c:137   /dev/drbd0: block size is 4096 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/drbd0
> >>>>>>>> device/dev-io.c:271   /dev/drbd0: size is 5611549368 sectors
> >>>>>>>> device/dev-io.c:535   Opened /dev/drbd0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:137   /dev/drbd0: block size is 4096 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/drbd0
> >>>>>>>>
> >>>>>>>> I interpret this: Look at /dev/md0, get some info, close; look at
> >> /dev/drbd0,
> >>>>>>>> get some info, close.
> >>>>>>>>
> >>>>>>>> Post-crash, I see:
> >>>>>>>>
> >>>>>>>> evice/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:271   /dev/md0: size is 1027968 sectors
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> device/dev-io.c:271   /dev/md0: size is 1027968 sectors
> >>>>>>>> device/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> filters/filter-composite.c:31   Using /dev/md0
> >>>>>>>> device/dev-io.c:535   Opened /dev/md0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:137   /dev/md0: block size is 1024 bytes
> >>>>>>>> label/label.c:186   /dev/md0: No label detected
> >>>>>>>> device/dev-io.c:588   Closed /dev/md0
> >>>>>>>> device/dev-io.c:535   Opened /dev/drbd0 RO O_DIRECT
> >>>>>>>> device/dev-io.c:271   /dev/drbd0: size is 5611549368 sectors
> >>>>>>>> device/dev-io.c:137   /dev/drbd0: block size is 4096 bytes
> >>>>>>>>
> >>>>>>>> ... and then it hangs. Comparing the two, it looks like it can't
> >> close /dev/drbd0.
> >>>>>>>>
> >>>>>>>> If I look at /proc/drbd when I crash one node, I see this:
> >>>>>>>>
> >>>>>>>> # cat /proc/drbd
> >>>>>>>> version: 8.3.12 (api:88/proto:86-96)
> >>>>>>>> GIT-hash: e2a8ef4656be026bbae540305fcb998a5991090f build by
> >>>>>>>> [email protected], 2012-02-28 18:01:34
> >>>>>>>>  0: cs:WFConnection ro:Primary/Unknown ds:UpToDate/DUnknown C
> s-----
> >>>>>>>>     ns:7000064 nr:0 dw:0 dr:7049728 al:0 bm:516 lo:0 pe:0 ua:0
> ap:0
> >> ep:1 wo:b oos:0
> >>>>>>>
> >>>>>>> s----- ... DRBD suspended io, most likely because of it's
> >>>>>>> fencing-policy. For valid dual-primary setups you have to use
> >>>>>>> "resource-and-stonith" policy and a working "fence-peer" handler.
> In
> >>>>>>> this mode I/O is suspended until fencing of peer was succesful.
> >> Question
> >>>>>>> is, why the peer does _not_ also suspend its I/O because obviously
> >>>>>>> fencing was not successful .....
> >>>>>>>
> >>>>>>> So with a correct DRBD configuration one of your nodes should
> already
> >>>>>>> have been fenced because of connection loss between nodes (on drbd
> >>>>>>> replication link).
> >>>>>>>
> >>>>>>> You can use e.g. that nice fencing script:
> >>>>>>>
> >>>>>>> http://goo.gl/O4N8f
> >>>>>>
> >>>>>> This is the output of "drbdadm dump admin": <
> >> http://pastebin.com/kTxvHCtx>
> >>>>>>
> >>>>>> So I've got resource-and-stonith. I gather from an earlier thread
> that
> >>>>>> obliterate-peer.sh is more-or-less equivalent in functionality with
> >>>>>> stonith_admin_fence_peer.sh:
> >>>>>>
> >>>>>> <http://www.gossamer-threads.com/lists/linuxha/users/78504#78504>
> >>>>>>
> >>>>>> At the moment I'm pursuing the possibility that I'm returning the
> >> wrong return
> >>>>>> codes from my fencing agent:
> >>>>>>
> >>>>>> <http://www.gossamer-threads.com/lists/linuxha/users/78572>
> >>>>>
> >>>>> I cleaned up my fencing agent, making sure its return code matched
> >> those
> >>>>> returned by other agents in /usr/sbin/fence_, and allowing for some
> >> delay issues
> >>>>> in reading the UPS status. But...
> >>>>>
> >>>>>> After that, I'll look at another suggestion with lvm.conf:
> >>>>>>
> >>>>>> <http://www.gossamer-threads.com/lists/linuxha/users/78796#78796>
> >>>>>>
> >>>>>> Then I'll try DRBD 8.4.1. Hopefully one of these is the source of
> the
> >> issue.
> >>>>>
> >>>>> Failure on all three counts.
> >>>>
> >>>> May I suggest you double check the permissions on your fence peer
> >> script?
> >>>> I suspect you may simply have forgotten the "chmod +x" .
> >>>>
> >>>> Test with "drbdadm fence-peer minor-0" from the command line.
> >>>
> >>> I still haven't solved the problem, but this advice has gotten me
> >> further than
> >>> before.
> >>>
> >>> First, Lars was correct: I did not have execute permissions set on my
> >> fence peer
> >>> scripts. (D'oh!) I turned them on, but that did not change anything:
> >> cman+clvmd
> >>> still hung on the vgdisplay command if I crashed the peer node.
> >>>
> >>> I started up both nodes again (cman+pacemaker+drbd+clvmd) and tried
> Lars'
> >>> suggested command. I didn't save the response for this message (d'oh
> >> again!) but
> >>> it said that the fence-peer script had failed.
> >>>
> >>> Hmm. The peer was definitely shutting down, so my fencing script is
> >> working. I
> >>> went over it, comparing the return codes to those of the existing
> >> scripts, and
> >>> made some changes. Here's my current script: <
> >> http://pastebin.com/nUnYVcBK>.
> >>>
> >>> Up until now my fence-peer scripts had either been Lon Hohberger's
> >>> obliterate-peer.sh or Digimer's rhcs_fence. I decided to try
> >>> stonith_admin-fence-peer.sh that Andreas Kurz recommended; unlike the
> >> first two
> >>> scripts, which fence using fence_node, the latter script just calls
> >> stonith_admin.
> >>>
> >>> When I tried the stonith_admin-fence-peer.sh script, it worked:
> >>>
> >>> # drbdadm fence-peer minor-0
> >>> stonith_admin-fence-peer.sh[10886]: stonith_admin successfully fenced
> >> peer
> >>> orestes-corosync.nevis.columbia.edu.
> >>>
> >>> Power was cut on the peer, the remaining node stayed up. Then I brought
> >> up the
> >>> peer with:
> >>>
> >>> stonith_admin -U orestes-corosync.nevis.columbia.edu
> >>>
> >>> BUT: When the restored peer came up and started to run cman, the clvmd
> >> hung on
> >>> the main node again.
> >>>
> >>> After cycling through some more tests, I found that if I brought down
> >> the peer
> >>> with drbdadm, then brought up with the peer with no HA services, then
> >> started
> >>> drbd and then cman, the cluster remained intact.
> >>>
> >>> If I crashed the peer, the scheme in the previous paragraph didn't
> work.
> >> I bring
> >>> up drbd, check that the disks are both UpToDate, then bring up cman. At
> >> that
> >>> point the vgdisplay on the main node takes so long to run that clvmd
> >> will time out:
> >>>
> >>> vgdisplay  Error locking on node orestes-corosync.nevis.columbia.edu:
> >> Command
> >>> timed out
> >>>
> >>> I timed how long it took vgdisplay to run. I might be able to work
> >> around this
> >>> by setting the timeout on my clvmd resource to 300s, but that seems to
> >> be a
> >>> band-aid for an underlying problem. Any suggestions on what else I
> could
> >> check?
> >>
> >> I've done some more tests. Still no solution, just an observation: The
> >> "death
> >> mode" appears to be:
> >>
> >> - Two nodes running cman+pacemaker+drbd+clvmd
> >> - Take one node down = one remaining node w/cman+pacemaker+drbd+clvmd
> >> - Start up dead node. If it ever gets into a state in which it's running
> >> cman
> >> but not clvmd, clvmd on the uncrashed node hangs.
> >> - Conversely, if I bring up drbd, make it primary, start cman+clvmd,
> >> there's no
> >> problem on the uncrashed node.
> >>
> >> My guess is that clvmd is getting the number of nodes it expects from
> >> cman. When
> >> the formally-dead node starts running cman, the number of cluster nodes
> >> goes to
> >> 2 (I checked with 'cman_tool status') but the number of nodes running
> >> clvmd is
> >> still 1, hence the crash.
> >>
> >> Does this guess make sense?
>
>
> --
> Bill Seligman             | Phone: (914) 591-2823
> Nevis Labs, Columbia Univ | mailto://[email protected]
> PO Box 137                |
> Irvington NY 10533 USA    | http://www.nevis.columbia.edu/~seligman/
>
>
> _______________________________________________
> Linux-HA mailing list
> [email protected]
> http://lists.linux-ha.org/mailman/listinfo/linux-ha
> See also: http://linux-ha.org/ReportingProblems
>



-- 